      The zinc power and silicon acid are served as main raw materials of ethyl ester and are added with macromolecule compound, thickener, filling, assistant agent and solvent, with A and B double-component packaging. The coating is high for zinc power content, has optimal cathodic protection function, has excellent weatherability can undertake long-term wind erosion, with outstanding oil resistance.


      Design Purpose

      It may be served as general anti-rust primer and may also be served as individual anti-corrosive paint.


      Physical Parameters

      Color

      Grey

       

      Luster

      Lightless

       

      Theoretical spreading rate

      330g/m2, 5.55m2/L (calculated in 60μm dry film, excluding the loss)

       

      Specific gravity:

      About 1.83

       

      Drying time

      23±2℃: surface dryness≦10 min, solid dryness≦24h

       

      Entirely cured

      23±2℃:3d

       

      Flash point

      13℃

       

      Storage period

      12 months for Component A; 6 months for Component B

      Construction Instruction

      Mixing ratio

      Component A ( paint ): Component B ( curing agent )=30:7.5


      Maturing time

      23±2℃; 0.5~1h


      Service life

      23±2℃; 8h


      Construction method

      High-pressure siphon spray; normal spray;  manual painting;  roller coating  


      Diluent

      X-11inorganic zinc rich coatingdiluent




      Maximal dilution amount

      High-pressure siphon spray

      Normal spray

      Manual painting;  roller coating

      5%

      10%

      3%


      0.4~0.5mm


      2.0~2.5mm

      -


      12~15Mpa


      0.3~0.4Mpa


      -

       


      Spray orifice

       


      Spray pressure

       


      Tool washing

      X-11inorganic zinc rich coatingdiluent


      Film coating thickness

      Wet film: 180μm                     Dry film: 120μm


      Coating interval

      Temperature of substrate

      5℃

      20℃

      30℃

      Shortest

      24h

      8h

      4h

      Longest

      Unlimit

       


      Surface treatment

      *The steel surface is required to be subjected to shotblasting or sandblasting method for treatment; as anti-rust paint, the coating surface is required to reach Grade Sa2.5 of Sweden Derusting Standard.

      *As anti-rust paint, the coating surface is required to reach Grade Sa3 of Sweden Derusting Standard.

      *The roughness reaches40-70μm.


      Construction condition

      The temperature of substrate must be 3℃ higher than dewing point, and the relative humidity must be less than 50%.

       

      Finishing paint

      Epoxy resin coating, epoxy asphalt coating,  oxide rubber coating,alkyd resin coating, polyurethane coating, highly chlorine polyethylene coating; the finish paint may not also be coated.

      Packing Specification

      30Kg/20L per barrel for Component A; 7.5Kg/10L per barrel for Component B

      Considerations

      *Since the content of zinc power is high, while allocating, it is suggested to employ the mechanical stirring to uniformly stir Component A, after that, add Component B and stir uniformly.

      *When the substrate temperature is≧30℃ but doesn’t exceed 60℃, in order to avoid dry spraying, the diluent must be added and regulated until no dry spraying;

      *Prior to coating the next pass of paint, the zinc salt on the surface must be eliminated thoroughly, otherwise, the adhesion force between paint film layers shall be affected.

      Safety guide  

      Avoid breathing solvent steam or paint fog for a long term; the skin and eye can’t contact this product; while constructing in the narrow place or poorly ventilated place, the forced ventilation must be provided; while constructing, the protective articles should be worn.

      Annotation

      *Above-said thickness of dry film and wet film refers to the index while implementing the high-pressure siphon spray;

      *Relevant data in this instruction is obtained from laboratory, the actual product may be slightly different from it;

      *If above data is changed, the data is based on the latest instruction, without prior notification.


    Tags: